Test Cycle: D2 Mode Cycle as mentioned under ISO 8178
Emission limits for new diesel engines ≤ 800 kW used in genset applications were set in 2002 and strengthened in 2013.
The regulations also set noise limits for diesel generator sets up to 1000 kVA. The table (CPCB – Phase I) summarizes the standards that became applicable in 2004/2005, and Table (CPCB – Phase II) lists the strengthened limits applicable from April 2014
P ≤ 19 kW
2004/01
2005/07
5.00
3.50
1.30
9.20
0.60
0.30
0.70
19 kW < P ≤ 50 kW
2004/07
0.50
50 kW < P ≤ 176 kW
176 kW < P ≤ 800 kW
2004/11
Ministry of Environment and Forest had issued a notification GSR 771 (E) dated 11th December, 2013 regarding the Emission Standards (CPCB Phase II) for New Diesel engines upto 800 kW for generator set (Genset application) which was effective from 1st April, 2014.
Further the implementation was amended vide GSR 232 (E), 31st March 2014 and made effective from 1st July, 2014. Subsequently, the certification requirements (Type Approval and COP for each COP year, for all engine models being manufactured or, for all engine or product models being imported) also revised from 1st July, 2014 and 1st July, 2015.
NOx +HC
CO
PM
Upto 19 KW
≤ 7.5
≤ 3.5
≤ 0.3
≤ 0.7
More than 19 KW upto 75 KW
≤ 4.7
More than 75 KW upto 800 KW
≤ 4.0
≤ 0.2
The Emission Standards for New Generator Sets (upto 19 kilowatt) run on Petrol and Kerosene is as under as per notification GSR 535 (E) dated 7th August, 2013.
Test Cycle:. D1-3 Mode Cycle as mentioned under ISO 8178: Part 4 (weighting factor of 0.3 for 100% load and 0.2 for 50 % load)
1
Upto 99
≤250
≤12
2
99 and upto 225
≤10
3
>225
≤8
The Ministry of Environment & Forests, Government of India, has notified Emissions standards for Diesel Gensets from 800 kW - 75 mW / 150 mW. (Ref. GSR # 489(E) dated 09-Jul-2002)